APPLICATION:
High voltage relay kit for 2-speed filter pump.
SPECIFICATIONS:
TYPE����DPDT
AMPS����20
PUMP����3 HP MAX.
- At the LX Power Center, remove service panel from right-side compartment
to expose high volatage section.
- Remove wingnut from mounting stud of relay kit, and position relay below
existing relays on compartment divider.
- Loosen LOCK SCREW of hinged faceplate (left-side compartment), and swing
it open to expose low voltage section.
- Feed low voltage connector of relay through lower hole, and mounting stud
through upper hole in compartment divider.
- Plug low voltage connector into circuit board at appropriate relay
socket.
- Snap terminal block into next available position on mounting track in