APPLICATION:
The Freeze Protection Sensor is designed to turn on the filter pump (or any other pump) when the outside air temperature falls below 35 degrees Fahrenheit. The circulating water helps prevent equipment from freeze damage.
For use on the following control systems:
CP2020, CP2000, CP1000, CP100/T, CP100/TL, CP30/T, CP30/TL, TIMEMASTER, SP100 control systems.
Caution: Do not use with the CP-3000 system (use part number FPS-3000).
INSTALLATION:
To install Freeze Sensor inside Power Center:
Disconnect appropriate relay from socket on circuit board, and plug 2-pin female connector (white) of Freeze Sensor. Plug 2-pin female connector (red) of Freeze Sensor into appropriate relay socket. Connect spare white wire of Freeze Sensor to "GND" screw terminal on circuit board.
To install Freeze Sensor outside Power Center:
Provide 2-conductor cable from low voltage compartment of Power Center to Sensor location. Cut wires (white) from harness, and connect to 2-conductor cable. At Power Center, strip insulation 1/4" and connect one wire to "GND" screw terminal on circuit board, and wire nut the other wire to spare white wire of Freeze Sensor in accordance with wiring diagram.